752N UV-Vis Spectrophotometer
Product Introduction
The
752N UV-Vis Spectrophotometer is a versatile analytical instrument designed for
routine laboratory testing, qualitative identification, and quantitative
analysis of substances in the ultraviolet-visible spectral region. Featuring
microprocessor-based control technology and an advanced holographic blazed
grating monochromator, it provides reliable wavelength selection, stable
measurement performance, and convenient operation.
Equipped
with a large backlit LCD display, the 752N UV-Vis Spectrophotometer allows
users to read measurement results clearly and efficiently. Its automatic 0% and
100% transmittance adjustment, concentration factor setting, and direct
concentration reading simplify routine analytical workflows. Optional serial
printer support and separately available UVWin7 software further extend its
data management and processing capabilities.
Performance Features
1. Advanced Holographic
Grating Monochromator: Uses a blazed holographic grating
monochromator to provide reliable wavelength accuracy, good monochromaticity,
and low stray light.
2. Large Backlit LCD
Display: Presents measurement data clearly for convenient observation during routine
laboratory testing.
3. Microprocessor-Based
Control: Provides efficient instrument control and reliable processing of measurement
signals.
4. Automatic
Transmittance Adjustment: Supports automatic 0%T and 100%T adjustment to
simplify instrument setup and measurement operations.
5. Direct Concentration
Reading: Allows users to set a concentration factor and obtain concentration results
directly for routine quantitative analysis.
6. Reliable Measurement
Performance: Offers good measurement accuracy, repeatability, and
stability for laboratory applications.
7. Optional Printing
Capability: Supports an optional serial printer for convenient
recording of measurement results.
8. UVWin7 Software
Compatibility: Separately available UVWin7 software expands data
processing and instrument operation capabilities, subject to software and
computer compatibility.
Working Principle
The
752N UV-Vis Spectrophotometer operates by measuring the interaction between
ultraviolet-visible light and a sample. Its optical system uses a holographic
blazed grating monochromator to separate light into selected wavelengths within
the 200–1000 nm range.
When
the selected light passes through a sample, some of the light may be absorbed
by the substance. The instrument measures the transmitted light intensity and
calculates transmittance or absorbance based on the measurement and reference
signals.
For
quantitative analysis, users can apply a concentration factor or an appropriate
calibration procedure to determine the concentration of the target substance.
The microprocessor-based measurement system processes the signals and displays
the results on the backlit LCD.
Technical Parameters
Parameter
Specification
Model
752N
Instrument
Type
UV-Vis
Spectrophotometer
Wavelength
Range
200–1000
nm
Maximum
Allowable Wavelength Error
±2
nm
Wavelength
Repeatability
≤1
nm
Maximum
Allowable Transmittance Error
±0.5%T
Transmittance
Error Test Standard
NBS930D
Transmittance
Repeatability
≤0.2%T
Spectral
Bandwidth
4
nm
Stray
Light
≤0.3%T
Stray
Light Test Conditions
220
nm with NaI; 360 nm with NaNO₂
Dark
Current Drift
0.2%T
/ 3 min
Bright
Current Drift
0.5%T
/ 3 min
Display
Large
backlit LCD
Control
System
Microprocessor-based
Data
Output and Software
Optional
serial printer; UVWin7 software sold separately
Dimensions
500
× 350 × 190 mm
Weight
14
kg
Power
Supply
AC
220 V ±22 V, 50 Hz ±1 Hz
Application Scenarios
The
752N UV-Vis Spectrophotometer is suitable for routine analytical measurements
in laboratories across a range of industries.
• Chemical
Analysis Laboratories: Quantitative concentration analysis and
absorbance measurements of chemical solutions.
• Educational
Institutions: UV-visible spectroscopy experiments and analytical
chemistry teaching.
• Environmental Testing: Analysis of
water and environmental samples using suitable UV-visible analytical methods.
• Pharmaceutical
Laboratories: Testing of compatible pharmaceutical substances and
formulations according to validated procedures.
• Industrial Quality
Control: Routine inspection of raw materials, intermediate products, and finished
products.
• Scientific
Research: Spectral measurements and quantitative studies in chemistry, materials science,
and related disciplines.
• General
Laboratory Testing: Routine transmittance and absorbance
measurements for compatible samples.
Comparison: 752N vs. General UV-Vis Spectrophotometers
Feature
752N UV-Vis Spectrophotometer
General UV-Vis Spectrophotometer
Wavelength
Range
200–1000
nm
Depends
on model
Monochromator
Holographic
blazed grating
Depends
on optical configuration
Spectral
Bandwidth
4
nm
Model-dependent
Wavelength
Accuracy
±2
nm
Model-dependent
Wavelength
Repeatability
≤1
nm
Model-dependent
Transmittance
Repeatability
≤0.2%T
Model-dependent
Display
Large
backlit LCD
Varies
by model
Concentration
Measurement
Concentration
factor setting and direct reading
Depends
on functions
Data
Management
Optional
printer and separately available UVWin7 software
Depends
on connectivity and software
Typical
Application
Routine
laboratory analysis and quantitative testing
Varies
by instrument capability
This comparison describes the 752N's documented
specifications against general instrument configurations, not a direct test
against a particular competing model.
Frequently Asked Questions
Q1: What is the wavelength range of the 752N UV-Vis
Spectrophotometer?
The
752N covers wavelengths from 200 to 1000 nm, supporting measurements in the
ultraviolet and visible spectral regions.
Q2: What is the spectral bandwidth of the 752N?
The
specified spectral bandwidth is 4 nm, suitable for many routine UV-visible
measurements.
Q3: Does the 752N support quantitative analysis?
Yes.
It supports concentration factor settings and direct concentration reading for
routine quantitative analysis. The appropriate measurement method and
calibration procedure depend on the sample and analytical requirements.
Q4: What are the wavelength accuracy and repeatability
specifications?
The
maximum allowable wavelength error is ±2 nm, and wavelength repeatability is ≤1
nm.
Q5: Can the 752N measure transmittance accurately?
The
specified maximum allowable transmittance error is ±0.5%T, while transmittance
repeatability is ≤0.2%T under the manufacturer's specified measurement
conditions.
Q6: Is computer software available for the 752N?
Yes.
UVWin7 software is available separately to expand the instrument's data
processing and operating capabilities. Confirm supported operating systems and
computer interfaces before purchase.
Q7: Can measurement results be printed?
An
optional serial printer is supported, allowing users to produce printed
measurement records when the compatible printer is configured.
Q8: What are the installation requirements for the 752N?
The
instrument measures 500 × 350 × 190 mm, weighs approximately 14 kg, and
requires an AC 220 V power supply with the specified voltage and frequency
tolerances. A stable laboratory bench and suitable environmental conditions are
recommended.
Q9: Which laboratories can use the 752N UV-Vis
Spectrophotometer?
It
is suitable for chemical, educational, environmental, pharmaceutical,
industrial quality control, and research laboratories performing compatible
UV-visible analyses.










