XI'AN YIMA OPTOELEC CO.,LTD

XI'AN YIMA OPTOELEC CO.,LTD

752N UV-Vis Spectrophotometer

Product Item: gdyq010
Category: Photoelectric detection instrument
Views: 1646
Supply Ability:50/month
Port:SHENZHEN
Model Number:752N
Payment Terms:T/T ,western union, paypal
price: Inquiry

  • PRODUCT DETAIL

752N UV-Vis Spectrophotometer

Product Introduction

The 752N UV-Vis Spectrophotometer is a versatile analytical instrument designed for routine laboratory testing, qualitative identification, and quantitative analysis of substances in the ultraviolet-visible spectral region. Featuring microprocessor-based control technology and an advanced holographic blazed grating monochromator, it provides reliable wavelength selection, stable measurement performance, and convenient operation.

Equipped with a large backlit LCD display, the 752N UV-Vis Spectrophotometer allows users to read measurement results clearly and efficiently. Its automatic 0% and 100% transmittance adjustment, concentration factor setting, and direct concentration reading simplify routine analytical workflows. Optional serial printer support and separately available UVWin7 software further extend its data management and processing capabilities.


Performance Features

1. Advanced Holographic Grating Monochromator: Uses a blazed holographic grating monochromator to provide reliable wavelength accuracy, good monochromaticity, and low stray light.

2. Large Backlit LCD Display: Presents measurement data clearly for convenient observation during routine laboratory testing.

3. Microprocessor-Based Control: Provides efficient instrument control and reliable processing of measurement signals.

4. Automatic Transmittance Adjustment: Supports automatic 0%T and 100%T adjustment to simplify instrument setup and measurement operations.

5. Direct Concentration Reading: Allows users to set a concentration factor and obtain concentration results directly for routine quantitative analysis.

6. Reliable Measurement Performance: Offers good measurement accuracy, repeatability, and stability for laboratory applications.

7. Optional Printing Capability: Supports an optional serial printer for convenient recording of measurement results.

8. UVWin7 Software Compatibility: Separately available UVWin7 software expands data processing and instrument operation capabilities, subject to software and computer compatibility.


Working Principle

The 752N UV-Vis Spectrophotometer operates by measuring the interaction between ultraviolet-visible light and a sample. Its optical system uses a holographic blazed grating monochromator to separate light into selected wavelengths within the 200–1000 nm range.

When the selected light passes through a sample, some of the light may be absorbed by the substance. The instrument measures the transmitted light intensity and calculates transmittance or absorbance based on the measurement and reference signals.

For quantitative analysis, users can apply a concentration factor or an appropriate calibration procedure to determine the concentration of the target substance. The microprocessor-based measurement system processes the signals and displays the results on the backlit LCD.


Technical Parameters

Parameter

Specification

Model

752N

Instrument Type

UV-Vis Spectrophotometer

Wavelength Range

200–1000 nm

Maximum Allowable Wavelength Error

±2 nm

Wavelength Repeatability

≤1 nm

Maximum Allowable Transmittance Error

±0.5%T

Transmittance Error Test Standard

NBS930D

Transmittance Repeatability

≤0.2%T

Spectral Bandwidth

4 nm

Stray Light

≤0.3%T

Stray Light Test Conditions

220 nm with NaI; 360 nm with NaNO₂

Dark Current Drift

0.2%T / 3 min

Bright Current Drift

0.5%T / 3 min

Display

Large backlit LCD

Control System

Microprocessor-based

Data Output and Software

Optional serial printer; UVWin7 software sold separately

Dimensions

500 × 350 × 190 mm

Weight

14 kg

Power Supply

AC 220 V ±22 V, 50 Hz ±1 Hz


Application Scenarios

The 752N UV-Vis Spectrophotometer is suitable for routine analytical measurements in laboratories across a range of industries.

• Chemical Analysis Laboratories: Quantitative concentration analysis and absorbance measurements of chemical solutions.

•  Educational Institutions: UV-visible spectroscopy experiments and analytical chemistry teaching.

•  Environmental Testing: Analysis of water and environmental samples using suitable UV-visible analytical methods.

• Pharmaceutical Laboratories: Testing of compatible pharmaceutical substances and formulations according to validated procedures.

•  Industrial Quality Control: Routine inspection of raw materials, intermediate products, and finished products.

• Scientific Research: Spectral measurements and quantitative studies in chemistry, materials science, and related disciplines.

• General Laboratory Testing: Routine transmittance and absorbance measurements for compatible samples.


Comparison: 752N vs. General UV-Vis Spectrophotometers

Feature

752N UV-Vis Spectrophotometer

General UV-Vis Spectrophotometer

Wavelength Range

200–1000 nm

Depends on model

Monochromator

Holographic blazed grating

Depends on optical configuration

Spectral Bandwidth

4 nm

Model-dependent

Wavelength Accuracy

±2 nm

Model-dependent

Wavelength Repeatability

≤1 nm

Model-dependent

Transmittance Repeatability

≤0.2%T

Model-dependent

Display

Large backlit LCD

Varies by model

Concentration Measurement

Concentration factor setting and direct reading

Depends on functions

Data Management

Optional printer and separately available UVWin7 software

Depends on connectivity and software

Typical Application

Routine laboratory analysis and quantitative testing

Varies by instrument capability

This comparison describes the 752N's documented specifications against general instrument configurations, not a direct test against a particular competing model.


Frequently Asked Questions

Q1: What is the wavelength range of the 752N UV-Vis Spectrophotometer?

The 752N covers wavelengths from 200 to 1000 nm, supporting measurements in the ultraviolet and visible spectral regions.

Q2: What is the spectral bandwidth of the 752N?

The specified spectral bandwidth is 4 nm, suitable for many routine UV-visible measurements.

Q3: Does the 752N support quantitative analysis?

Yes. It supports concentration factor settings and direct concentration reading for routine quantitative analysis. The appropriate measurement method and calibration procedure depend on the sample and analytical requirements.

Q4: What are the wavelength accuracy and repeatability specifications?

The maximum allowable wavelength error is ±2 nm, and wavelength repeatability is ≤1 nm.

Q5: Can the 752N measure transmittance accurately?

The specified maximum allowable transmittance error is ±0.5%T, while transmittance repeatability is ≤0.2%T under the manufacturer's specified measurement conditions.

Q6: Is computer software available for the 752N?

Yes. UVWin7 software is available separately to expand the instrument's data processing and operating capabilities. Confirm supported operating systems and computer interfaces before purchase.

Q7: Can measurement results be printed?

An optional serial printer is supported, allowing users to produce printed measurement records when the compatible printer is configured.

Q8: What are the installation requirements for the 752N?

The instrument measures 500 × 350 × 190 mm, weighs approximately 14 kg, and requires an AC 220 V power supply with the specified voltage and frequency tolerances. A stable laboratory bench and suitable environmental conditions are recommended.

Q9: Which laboratories can use the 752N UV-Vis Spectrophotometer?

It is suitable for chemical, educational, environmental, pharmaceutical, industrial quality control, and research laboratories performing compatible UV-visible analyses.

PREVIOUS:L6 UV-Vis Spectrophotometer
NEXT:ZDY-502 Karl Fischer Water Titration Apparatus

Live chat X

Skype

WhatsApp

QQ
Email me

Mail to us

Leave a message