5B-1B Intelligent Dual-Temperature-Zone Digestion Device

Product Introduction

The 5B-1B Intelligent Dual-Temperature-Zone Digestion Device is a laboratory sample preparation instrument designed for water quality analysis, including chemical oxygen demand (COD), total phosphorus, and total nitrogen testing. Its dual-zone heating system allows water samples requiring different digestion temperatures to be processed simultaneously, improving laboratory efficiency and reducing sample preparation time.

The 5B-1B-1 (V8) model features 30 numbered digestion positions, with additional positions available for customization according to user requirements. Its adjustable digestion temperature and timing functions support different analytical procedures, while intelligent heating control automatically stops heating when the preset digestion time is reached.

Equipped with a transparent, integrated splash-resistant safety cover, an insulated digestion block, and a liquid crystal display, the instrument combines operational convenience, temperature stability, and enhanced user protection. It is suitable for environmental monitoring laboratories, water quality testing facilities, wastewater treatment plants, and industrial laboratories.


Performance Features

•  Dual-Temperature-Zone Heating: Processes two groups of water samples at different temperatures simultaneously, improving laboratory throughput.

• 30 Digestion Positions: Provides 30 numbered digestion holes, with customized configurations available upon request.

•  Rapid Heating: Heats from room temperature to 165°C within approximately 10 minutes under the specified conditions.

•  Precise Temperature Control: Offers a specified temperature accuracy of ±0.5°C.

•  Adjustable Digestion Parameters: Allows users to set digestion temperatures and durations according to analytical requirements.

•  Intelligent Heating Control: Automatically stops heating when the preset digestion time is completed.

• Delayed Start and Protection: Supports preset timing functions to help manage heating schedules and reduce unnecessary energy consumption.

•  Automatic Temperature-Ready Operation: When samples are prepared and the system is waiting, heating and digestion operations proceed according to the configured temperature and program settings.

• Integrated Safety Cover: The transparent, heat-resistant splash-protection cover allows users to observe samples during digestion.

• Thermal Insulation: An aviation-grade insulation layer helps reduce surface heat exposure and improve operating safety.

•  Built-In Digestion Programs: Provides three preset digestion procedures for convenient operation.

•  Flexible Digestion Tube Compatibility: Supports optional tube diameters of 16 mm or 20 mm.


Working Principle

The 5B-1B intelligent digestion device uses controlled electrical heating to raise water samples and digestion reagents to specified temperatures for a defined period. This controlled thermal treatment prepares samples for subsequent water quality analysis.

1. Dual-Zone Temperature Control

The instrument uses two independently configured temperature zones to accommodate samples requiring different digestion temperatures. This enables parallel sample preparation without requiring separate digestion cycles for each temperature condition.

2. Programmable Heating and Timing

Users set the required digestion temperature and duration according to the analytical method. The device regulates heating to maintain the target temperature and automatically stops heating when the preset digestion time has elapsed.

3. Intelligent Operation

The instrument incorporates preset digestion programs and temperature-based operating logic. Once the required conditions are reached, the system proceeds according to the selected settings, simplifying routine sample preparation.

4. Safe Sample Digestion

A transparent, integrated splash-resistant cover helps contain splashes while allowing visual observation. The insulated digestion block helps reduce heat exposure during operation.

After digestion, the prepared samples can be used in compatible analytical procedures for COD, total phosphorus, total nitrogen, and other supported applications.


Technical Parameters

Parameter

Specification

Product Model

5B-1B-1 (V8)

Product Type

Intelligent Dual-Temperature-Zone Digestion Device

Digestion Positions

30

Customized Capacity

Additional digestion positions available on request

Heating Speed

Room temperature to 165°C in 10 minutes

Temperature Accuracy

±0.5°C

Digestion Temperature

Ambient temperature to 190°C, user-settable

Digestion Programs

3 preset procedures

Supported Applications

COD, total phosphorus, total nitrogen digestion

Digestion Capacity

0–10 mL

Digestion Tube Diameter

Ø16 mm / Ø20 mm, optional

Digestion Tube Height

150 mm

Heating Liquid Depth

80 mm

Timing Precision

0.2, as specified by the manufacturer

Timing Switch

6, as specified by the manufacturer

Display

LCD

Operating Keys

9

Dual-Temperature-Zone Function

Supported

Splash Protection

Integrated transparent safety cover

Delayed Protection

Supported

Intelligent Heating

Supported

Note: The supplied specifications list timing precision as “0.2” without a clearly defined unit and timing switch as “6.” Confirm the exact meanings and timing range with the manufacturer before publication or purchase.


Application Scenarios

•  Environmental Monitoring Laboratories: Digestion of water samples before chemical analysis.

• COD Analysis: Thermal digestion of samples for chemical oxygen demand determination using a compatible analytical method.

• Total Phosphorus Testing: Sample digestion before phosphorus measurement.

• Total Nitrogen Analysis: Preparation of water samples for total nitrogen determination using compatible procedures.

•  Wastewater Treatment Plants: Routine preparation of influent, effluent, and process water samples.

•  Industrial Water Quality Testing: Digestion of samples from manufacturing, power generation, and industrial wastewater systems.

•  Research and Teaching Laboratories: Parallel digestion of samples under different temperature conditions.

• Third-Party Testing Laboratories: Batch sample preparation for routine environmental and water quality testing.


5B-1B vs. Conventional Single-Temperature Digestion Device

Feature

5B-1B Intelligent Dual-Zone Digestion Device

Conventional Single-Zone Digestion Device

Temperature Zones

2

Typically 1

Simultaneous Different-Temperature Digestion

Supported

Generally requires separate cycles

Standard Digestion Positions

30

Depends on model

Temperature Accuracy

±0.5°C

Model-dependent

Maximum Set Temperature

190°C

Model-dependent

Heating Control

Intelligent, programmable

Depends on model

Automatic Heating Stop

Supported

Model-dependent

Preset Digestion Programs

3

Model-dependent

Sample Observation

Transparent integrated safety cover

Depends on model

Digestion Tube Options

Ø16 mm / Ø20 mm

Depends on model

Typical Advantage

Greater flexibility for mixed-temperature workflows

Suitable for routine digestion at one temperature


Frequently Asked Questions

1. What is the 5B-1B digestion device used for?

It is designed for laboratory digestion of water samples for COD, total phosphorus, total nitrogen, and related water quality analysis procedures.

2. What is the advantage of its dual-temperature-zone design?

The two heating zones allow samples requiring different digestion temperatures to be processed simultaneously, reducing waiting time and improving laboratory efficiency.

3. How many samples can the 5B-1B process at once?

The standard configuration provides 30 numbered digestion positions. Additional positions may be customized according to user requirements.

4. What is the maximum digestion temperature?

The adjustable digestion temperature ranges from ambient temperature to 190°C.

5. How accurate is the temperature control?

The specified temperature accuracy is ±0.5°C.

6. How quickly does the instrument heat up?

The specified heating speed is from room temperature to 165°C in approximately 10 minutes. Actual heating performance may depend on ambient conditions, sample loading, and operating conditions.

7. Which digestion tubes are compatible with the instrument?

The device supports digestion tubes with diameters of 16 mm or 20 mm, depending on the selected configuration. The specified tube height is 150 mm.

8. Does the device automatically stop heating?

Yes. Intelligent heating control automatically stops heating when the preset digestion time is reached.

9. What safety features are included?

The device features an integrated transparent, heat-resistant splash-protection cover and an insulated digestion block designed to help reduce heat exposure.

10. Can the digestion capacity be customized?

Yes. The standard configuration has 30 digestion positions, and additional digestion holes can be customized according to the user's requirements.

 


PREVIOUS:CS300X Multi-Channel Electrochemical Workstation
NEXT:5B-3B(V8) Intelligent Multi-Parameter Water Quality Analyzer

Live chat X

Skype

WhatsApp

QQ
Email me

Mail to us

Leave a message