CU-600S Online Total Organic Carbon (TOC) Analyzer
Product Introduction
The CU-600S Online Total Organic Carbon (TOC) Analyzer is designed for continuous monitoring of organic carbon in high-purity water systems. It is suitable for pharmaceutical water preparation and distribution systems, semiconductor manufacturing and wafer-processing water systems, power plant deionized water preparation, and scientific research applications.
The CU-600S measures total organic carbon (TOC), conductivity, and temperature, enabling users to monitor multiple water-quality parameters through one compact instrument. Its 3.5-inch touchscreen provides an intuitive operating interface, while built-in data storage supports up to five years of records with daily queries.
Designed for convenient operation and reduced routine maintenance, the analyzer does not require carrier gas or chemical reagents according to the supplied specifications. An external sampling device can be used for offline laboratory testing, and an optional 4–20 mA output supports integration with compatible monitoring or control systems. A built-in stylus printer provides local data printing in a compact design.
Performance Features
1. Online TOC monitoring: Measures total organic carbon in high-purity water systems for continuous water-quality supervision.
2. Wide TOC detection range: Covers 0.1–1500.0 μg/L, according to the supplied specifications.
3. Multi-parameter measurement: Measures TOC, conductivity, and temperature in one instrument.
4. High-sensitivity measurement: The stated TOC detection precision is 0.1 μg/L.
5. Simple touchscreen operation: A 3.5-inch touchscreen offers a straightforward human-machine interface.
6. No carrier gas or reagents: The specified configuration avoids routine carrier-gas and reagent requirements, helping simplify maintenance.
7. Long-term data storage: Stores up to five years of data and supports daily record queries.
8. Built-in printer: An integrated stylus printer enables local printing while minimizing external equipment requirements.
9. Optional analog output: An external 4–20 mA output is available for compatible process monitoring and control systems.
10. Flexible sampling: Water-pressure sampling supports online monitoring; an external sampling device can support offline laboratory testing.
11. Compact construction: The small footprint supports installation in laboratory and water-system monitoring areas.
12. Multiple industrial applications: Suitable for pharmaceutical, semiconductor, power generation, and scientific research water systems.
Working Principle
A total organic carbon analyzer determines the amount of organic carbon present in a water sample by converting organic compounds into a measurable carbon-containing species and quantifying the resulting signal. The CU-600S is specified for online TOC measurement together with conductivity and temperature monitoring.
The analyzer receives water through a pressure-based sampling arrangement and processes the sample to obtain TOC measurement results. Conductivity and temperature are measured as additional water-quality parameters. Results can be viewed on the touchscreen and stored for subsequent review.
The supplied product information does not specify the exact TOC oxidation and detection method. Buyers should confirm the analytical principle, calibration procedure, and suitability for their required water-quality standards with the manufacturer.
Technical Parameters
|
Parameter |
Specification |
|
Product model |
CU-600S |
|
Product type |
Online total organic carbon (TOC) analyzer |
|
Measurement items |
TOC, conductivity, temperature |
|
TOC detection range |
0.1–1500.0 μg/L |
|
Conductivity detection range |
0.055–6.000 μS/cm |
|
TOC detection precision |
0.1 μg/L |
|
Accuracy error |
≤±5% |
|
Repeatability error |
≤3% |
|
Zero drift |
±2%/day |
|
Span drift |
±2%/day |
|
Response time |
≤15 minutes |
|
Sample temperature |
0–100°C |
|
Sampling method |
Water pressure |
|
Operating ambient temperature |
0–60°C |
|
Relative humidity |
≤90% |
|
Display |
3.5-inch touchscreen |
|
Data storage |
Up to 5 years |
|
Data query |
Daily record query |
|
Printer |
Built-in stylus printer |
|
Analog output |
External 4–20 mA output, optional |
|
Carrier gas / reagents |
Not required according to the supplied specifications |
|
Power supply |
220 V AC, 50 Hz, ±10% |
|
Power consumption |
60 W |
|
Dimensions |
30.5 × 12.6 × 16.8 cm |
|
Weight |
6 kg |
Note: Confirm whether the stated conductivity range represents the intended measurement range for the target water system, and verify the TOC detection method and calibration requirements before purchase.
Application Scenarios
The CU-600S online TOC analyzer is intended for water systems where low-level organic contamination must be monitored.
• Pharmaceutical water systems: Online TOC monitoring during preparation and distribution of purified water or other applicable pharmaceutical water.
• Semiconductor manufacturing: Monitoring high-purity water used in wafer processing and related manufacturing systems.
• Power plants: Monitoring deionized water preparation and associated high-purity water processes.
• Scientific research laboratories: Measuring water samples and monitoring water quality in laboratory systems.
• Offline sample testing: Using an external sampling device for laboratory analysis when configured for the required sampling arrangement.
• Industrial water-quality control: Providing TOC, conductivity, and temperature information for compatible monitoring systems.
The instrument's suitability for a specific regulated process depends on the applicable standards, validation requirements, and manufacturer documentation.
CU-600S vs. Conventional TOC Monitoring Solutions
|
Feature |
CU-600S Online TOC Analyzer |
Conventional TOC Monitoring Solution |
|
Monitoring mode |
Designed for online monitoring |
May require manual or laboratory sampling |
|
Measurement parameters |
TOC, conductivity, and temperature |
May measure TOC alone or require separate instruments |
|
TOC range |
0.1–1500.0 μg/L |
Depends on instrument model |
|
User interface |
3.5-inch touchscreen |
Interface varies |
|
Data storage |
Up to 5 years, with daily queries |
Storage capacity varies |
|
Printing |
Built-in stylus printer |
May require an external printer |
|
Analog integration |
Optional 4–20 mA output |
Depends on model and configuration |
|
Routine consumables |
No carrier gas or reagents specified |
Requirements vary by analytical technology |
|
Installation footprint |
Compact, 30.5 × 12.6 × 16.8 cm |
Depends on system design |
|
Typical applications |
Pharmaceutical, semiconductor, power plant, and research water systems |
Depends on application and performance requirements |
Frequently Asked Questions (FAQ)
Q1: What is the CU-600S online TOC analyzer used for?
It is used to monitor total organic carbon in high-purity water systems, including pharmaceutical water preparation, semiconductor wafer processing, power plant deionized water systems, and research laboratories.
Q2: What is the TOC detection range of the CU-600S?
The specified TOC detection range is 0.1–1500.0 μg/L.
Q3: Can the CU-600S measure parameters other than TOC?
Yes. The instrument is specified to measure TOC, conductivity, and temperature.
Q4: Does the analyzer require carrier gas or chemical reagents?
The supplied specifications state that carrier gas and reagents are not required. Confirm the detailed analytical method and maintenance requirements with the manufacturer.
Q5: How long can measurement data be stored?
The analyzer supports up to five years of data storage and daily record queries, according to the product information.
Q6: Does the CU-600S support connection to an external control system?
An external 4–20 mA output is available as an option. Confirm the output configuration and compatibility with the receiving control or monitoring system.
Q7: What is the response time?
The specified response time is 15 minutes or less. Actual performance may depend on sampling conditions and operating configuration.
Q8: Can the analyzer be used for offline laboratory samples?
The supplied information describes an external sampling device for offline sample testing. Confirm the required accessory and operating procedure for the intended laboratory setup.
Q9: What are the installation requirements?
The instrument requires a 220 V AC, 50 Hz power supply with ±10% tolerance. The stated power consumption is 60 W, dimensions are 30.5 × 12.6 × 16.8 cm, and weight is 6 kg. Ensure that sample temperature, ambient temperature, humidity, and water-pressure sampling conditions are within the specified limits.










