FC-9624YLAB Online Water Quality Over-Standard Sample Retainer
Product Introduction
The FC-9624YLAB Online Water Quality Over-Standard Sample Retainer is an automatic water sampling and sample preservation system designed for online water quality monitoring and pollution source monitoring applications. It integrates automatic sampling, mixed-sample preparation, sample distribution, refrigerated sample retention, automatic pipeline rinsing, and sampling record management in one system.
Equipped with 24 polyethylene sample bottles with a capacity of 1,000 mL each, the FC-9624YLAB can retain samples according to configurable sampling requirements and provide mixed water samples to online monitoring instruments for parameters such as chemical oxygen demand (COD), ammonia nitrogen, total phosphorus, total nitrogen, and heavy metals.
The system supports time-based composite sampling, flow-proportional sampling when equipped with a dedicated flow probe, external-control sampling triggered by water quality thresholds, and remote manual sampling. Its sample storage temperature is maintained at 4 ± 2°C, helping preserve collected samples under the specified operating conditions.
With automatic mixing, draining, backflushing, and rinsing functions, the FC-9624YLAB is designed to improve sampling consistency and reduce manual intervention in continuous water quality monitoring workflows.
Performance Features
1. Multiple Sampling Modes: Supports time-based composite sampling, flow-proportional sampling with a dedicated flow probe, external-control sampling based on over-limit parameters, and remote random sampling.
2. Over-Standard Triggered Sampling: Accepts external control signals associated with parameters such as COD, ammonia nitrogen, total phosphorus, total nitrogen, and heavy metals.
3. Flexible Sample Retention: Supports sample retention in 1–24 bottles, with configurable bottle quantity and retention mode.
4. 24-Bottle Sample Storage: Standard configuration includes 24 polyethylene bottles, each with a 1,000 mL capacity. Alternative bottle configurations are available.
5. Integrated Mixing Function: The buffer box incorporates mixing to help provide mixed water samples to connected online monitoring instruments.
6. Automatic Drainage and Rinsing: Automatically drains residual water from the buffer box and rinses the sampling pipeline before the next sampling cycle.
7. Refrigerated Sample Preservation: Maintains the specified sample storage temperature at 4 ± 2°C.
8. Comprehensive Sampling Records: Stores up to 8,000 sampling records, including sample time, bottle number, retained volume, and over-standard information, with cyclic updating.
9. Door-Status Monitoring: Records sampler door opening and closing events, retaining the latest 2,000 records.
10. Power-Failure Records and Recovery: Records power-off and power-on events and can restore the previous operating state after power is restored.
11. Multiple Communication Interfaces: Provides RS-232, RS-485, and 4–20 mA signal interfacing as specified.
12. Touchscreen Operation: Features a 2.8-inch TFT color LCD touchscreen with a Chinese-language interface for convenient operation and parameter configuration.
13. Voice Broadcast: Includes a voice broadcast function to support operational notifications.
14. Automatic Sample Distribution: Uses a 24-bottle distribution system with a mechanical self-locking function to support controlled sample allocation.
Working Principle
The FC-9624YLAB operates by collecting water samples according to preset schedules, flow conditions, external control signals, or remote commands.
1. Sampling Control
The sampler initiates collection according to the selected mode. Sampling intervals can be configured from 5 to 9,999 minutes. When used for flow-proportional sampling, a dedicated flow probe is required. Over-standard sampling depends on compatible external monitoring or control signals.
2. Buffering and Mixing
Collected water enters the buffer box, where the integrated mixing function helps prepare a representative mixed sample for connected online monitoring instruments.
3. Sample Distribution and Retention
The system distributes water into the selected sample bottles according to the configured bottle quantity, retention mode, and sampling volume. The sample volume can be set from 10 to 1,000 mL in 10 mL increments.
4. Temperature-Controlled Preservation
Collected samples are stored under the specified temperature condition of 4 ± 2°C to support sample preservation before subsequent analysis.
5. Automatic Draining and Rinsing
After the relevant sampling operation, the system can drain residual water from the buffer box and backflush or rinse the sampling pipeline before the next cycle. This helps reduce residual-water carryover and supports consistent sampling.
6. Data Recording and Communication
The instrument records sampling events and relevant information, including timestamps, bottle numbers, sample volumes, and over-standard signals. Communication interfaces support integration with compatible monitoring and control systems.
Technical Parameters
|
Parameter |
Specification |
|
Model |
FC-9624YLAB |
|
Instrument Type |
Online Water Quality Over-Standard Sample Retainer |
|
Standard Sample Bottles |
24 bottles |
|
Sample Bottle Material |
Polyethylene |
|
Capacity per Bottle |
1,000 mL |
|
Optional Bottle Configurations |
2, 3, 4, 6, 8, or 12 bottles |
|
Sampling Volume |
10–1,000 mL, adjustable in 10 mL increments |
|
Pumping Speed |
3,700 mL/min |
|
Vertical Sampling Height |
8.7 m |
|
Horizontal Sampling Distance |
80 m |
|
Sampling Interval |
5–9,999 minutes, adjustable |
|
Sampling Modes |
Time-based composite, flow-proportional, external-control over-standard, and remote sampling |
|
Sample Distribution |
24-bottle distribution system with mechanical self-locking |
|
Sample Volume Error |
±10 mL or ≤5% when sample volume is ≥200 mL |
|
System Clock Timing Error |
0.03% and ≤2 s, as specified |
|
Sample Storage Temperature |
4 ± 2°C |
|
Pipeline Airtightness |
≤−0.08 MPa |
|
Mean Time Between Failures (MTBF) |
1,440 h |
|
Insulation Resistance |
>20 MΩ |
|
Working Temperature |
−5°C to +50°C |
|
Relative Humidity |
≤90% |
|
Sampling Record Capacity |
8,000 records, cyclic updating |
|
Door Event Records |
Latest 2,000 records |
|
Power Event Records |
Latest 2,000 records |
|
Communication Interfaces |
RS-232, RS-485, 4–20 mA |
|
Display |
2.8-inch TFT color LCD touchscreen |
|
Operating Interface |
Chinese-language interface |
|
Power Supply |
AC 220 V ±15%, 50 Hz |
|
Average Power Consumption |
73 W |
Note: Confirm signal wiring, compatible external control protocols, flow probe configuration, and refrigeration operating conditions with the manufacturer before installation. The supplied specifications list 4–20 mA as a communication interface; verify the exact input/output configuration for the intended system.
Application Scenarios
The FC-9624YLAB is designed for automated water sampling and sample retention in environmental monitoring and industrial wastewater management.
- Industrial Wastewater Monitoring: Collects and retains samples from industrial discharge outlets for subsequent water quality analysis.
- Pollution Source Monitoring: Supports automatic sample collection when monitored parameters exceed configured thresholds, subject to compatible external signals.
- COD Monitoring: Provides mixed water samples to compatible online COD analyzers.
- Nutrient Monitoring: Supports sample supply for ammonia nitrogen, total phosphorus, and total nitrogen monitoring systems.
- Heavy Metal Monitoring: Retains water samples for connected monitoring equipment or subsequent laboratory analysis of heavy metals.
- Environmental Monitoring Stations: Supports unattended sampling workflows and traceable sample records.
- Municipal Wastewater Facilities: Can be incorporated into wastewater monitoring systems where the installation and sampling requirements are compatible.
- Automated Monitoring Networks: Uses serial communication and signal interfaces to integrate with suitable monitoring and control equipment.
FC-9624YLAB vs. Conventional Automatic Water Samplers
|
Comparison Item |
FC-9624YLAB |
Conventional Automatic Water Sampler |
|
Sampling Modes |
Time-based, flow-proportional, external-control over-standard, and remote sampling |
Depends on model |
|
Sample Bottle Configuration |
Standard 24 × 1,000 mL; alternative configurations available |
Depends on model |
|
Mixed-Sample Supply |
Integrated buffer-box mixing |
May require separate mixing equipment |
|
Sample Distribution |
Automatic distribution with mechanical self-locking |
Depends on distribution design |
|
Sample Preservation |
Specified storage temperature of 4 ± 2°C |
Depends on model and preservation system |
|
Pipeline Maintenance |
Automatic draining, backflushing, and rinsing |
May require manual or separate cleaning |
|
Sampling Records |
8,000 records with cyclic updating |
Depends on data logging capacity |
|
Door and Power Event Logs |
Latest 2,000 records for each specified event category |
Not available on all models |
|
Communication |
RS-232, RS-485, and specified 4–20 mA interface |
Depends on model |
|
User Interface |
2.8-inch color touchscreen |
Depends on model |
This comparison is based on the supplied specifications and general equipment categories. Actual capabilities vary by sampler configuration.
Frequently Asked Questions (FAQ)
1. What is the FC-9624YLAB water quality sample retainer used for?
It automatically collects, mixes, distributes, and retains water samples for online water quality monitoring and pollution source monitoring applications.
2. How many sample bottles does the FC-9624YLAB support?
Its standard configuration includes 24 polyethylene bottles with a capacity of 1,000 mL each. Optional configurations with 2, 3, 4, 6, 8, or 12 bottles are also listed.
3. What sampling modes are available?
The system supports time-based composite sampling, flow-proportional sampling with a dedicated flow probe, externally triggered over-standard sampling, and remote random sampling.
4. Can it collect samples automatically when water quality exceeds a threshold?
Yes. It supports external-control sampling triggered by over-standard conditions. Compatible monitoring or control equipment must provide the required signals, and the trigger logic should be configured for the intended application.
5. What water quality parameters can it support?
It can provide mixed samples to compatible online monitoring instruments for COD, ammonia nitrogen, total phosphorus, total nitrogen, and heavy metals. The sampler itself is not specified as directly measuring these parameters.
6. What is the sample storage temperature?
The specified water sample storage temperature is 4 ± 2°C. Confirm the refrigeration configuration and its operating limits with the manufacturer.
7. How much sample can be collected in one operation?
The sampling volume is adjustable from 10 to 1,000 mL in increments of 10 mL. The specified sample volume error is ±10 mL or ≤5% when the sample volume is at least 200 mL.
8. Does the FC-9624YLAB clean its sampling pipeline automatically?
Yes. It can automatically drain residual water from the buffer box and perform backflushing and rinsing of the sampling pipeline before the next sampling cycle.
9. What data and communication functions are available?
The instrument can store up to 8,000 sampling records with cyclic updating and retain the latest 2,000 door-event records and 2,000 power-event records. Interfaces include RS-232, RS-485, and a specified 4–20 mA connection; confirm the exact signal configuration for integration.