XI'AN YIMA OPTOELEC CO.,LTD

XI'AN YIMA OPTOELEC CO.,LTD

Laser532-0.2-100-FC-1A 532nm Stable Spectrum Laser

Product Item: gdyq024
Category: Photoelectric detection instrument
Views: 1283
Supply Ability:50/month
Port:SHENZHEN
Model Number:Laser532-0.2-100-FC-1A
Payment Terms:T/T ,paypal
price: Inquiry

  • PRODUCT DETAIL

Laser532-0.2-100-FC-1A 532nm Stable Spectrum Laser

Product Introduction

The Laser532-0.2-100-FC-1A 532nm Stable Spectrum Laser is a compact, low-power-consumption laser source designed for Raman spectroscopy and other optical analysis applications requiring stable wavelength, narrow linewidth, and consistent output power.

Operating at a peak wavelength of 532 nm ± 0.5 nm, this green laser provides adjustable output power from 0 to 100 mW, allowing users to optimize excitation intensity for different samples and measurement conditions. With an excitation linewidth below 0.2 nm, power stability better than 3% peak-to-peak over two hours, and a specified lifetime of 5,000 hours, it offers a practical excitation source for Raman analysis systems and laboratory optical instruments.

Its compact dimensions, lightweight design, and FC output connection support convenient integration into compatible optical equipment.


Performance Features

•  532 nm Green Laser Output: Provides a peak wavelength of 532 nm ± 0.5 nm for Raman excitation and optical analysis.

• Narrow Linewidth: Excitation linewidth below 0.2 nm supports consistent spectral excitation.

•  Stable Optical Performance: Output power stability of less than 3% peak-to-peak over two hours.

• Adjustable Output Power: Power can be adjusted from 0 to 100 mW to accommodate different samples and experimental requirements.

•  Compact and Lightweight: Measures 180 × 44 × 42 mm and weighs only 230 g.

• Low Power Consumption: Designed for efficient integration into compact optical systems.

• FC Output Connection: Provides an FC output interface for connection to compatible optical components.

• 5,000-Hour Laser Lifetime: Specified operating lifetime supports routine laboratory use.

•  Defined Warm-Up Time: A 15-minute warm-up period helps prepare the laser for operation.


Working Principle

The 532 nm stable spectrum laser generates monochromatic green laser light for use as an optical excitation source. When integrated into a Raman spectroscopy system, the laser illuminates the sample, and the scattered light is collected and analyzed to obtain Raman spectral information associated with the sample's molecular structure.

The narrow excitation linewidth helps provide a well-defined laser source, while wavelength and output power stability support repeatable measurement conditions. Adjustable output power allows users to select an appropriate excitation level according to sample properties and testing requirements.


Technical Parameters

Parameter

Specification

Model

Laser532-0.2-100-FC-1A

Product Type

532 nm Stable Spectrum Laser

Peak Wavelength

532 nm ± 0.5 nm

Excitation Linewidth

< 0.2 nm

Output Power

0–100 mW, adjustable

Power Stability

< 3% P-P over 2 hours

Specified Laser Lifetime

5,000 hours

Output Method

FC

Warm-Up Time

15 minutes

Dimensions

180 × 44 × 42 mm

Weight

230 g


Application Scenarios

• Raman Spectroscopy: Provides laser excitation for compatible Raman spectrometers and analytical systems.

• Laboratory Optical Analysis: Serves as a stable green laser source for optical measurement setups.

• Material Characterization: Supports optical experiments involving material identification and spectral analysis.

•  Scientific Research: Suitable for laboratory experiments requiring controlled laser wavelength and adjustable output power.

• Optical Instrument Integration: Can be integrated into compatible instruments using an FC optical connection.

•  Spectroscopic System Development: Provides an excitation source for the development and testing of optical analysis equipment.


532nm Stable Spectrum Laser vs. General-Purpose Laser Sources

Comparison Item

Laser532-0.2-100-FC-1A

General-Purpose Laser Source

Peak Wavelength

532 nm ± 0.5 nm

Depends on model

Excitation Linewidth

< 0.2 nm

Depends on model

Output Power

Adjustable from 0 to 100 mW

Depends on model

Power Stability

< 3% P-P over 2 hours

Depends on model

Output Connection

FC

Varies by design

Specified Lifetime

5,000 hours

Depends on model

Typical Application

Raman excitation and optical analysis

General illumination, alignment, or optical applications

Integration

Compact, lightweight design

Varies by configuration

Note: Actual suitability depends on the required wavelength, optical coupling, power stability, and specifications of the target instrument.


Frequently Asked Questions

Q1: What is the Laser532-0.2-100-FC-1A used for?

It is a 532 nm stable spectrum laser designed primarily as an excitation source for Raman spectroscopy and compatible optical analysis systems.

Q2: What is the output wavelength of this laser?

The specified peak wavelength is 532 nm ± 0.5 nm, corresponding to green visible laser light.

Q3: Is the laser output power adjustable?

Yes. The output power is adjustable from 0 to 100 mW, allowing users to select an appropriate power level for different samples and experimental conditions.

Q4: What is the excitation linewidth?

The specified excitation linewidth is less than 0.2 nm, supporting narrowband optical excitation.

Q5: How stable is the laser output power?

The specified power stability is less than 3% peak-to-peak over a two-hour period.

Q6: What output connection does the laser use?

The laser uses an FC output connection. Users should confirm connector compatibility with the optical fiber and equipment in their system.

Q7: How long is the laser's service life?

The specified laser lifetime is 5,000 hours. Actual service life depends on operating conditions, thermal management, and usage.

Q8: How long does the laser need to warm up?

The specified warm-up time is 15 minutes. Allowing the recommended warm-up period can help establish stable operating conditions before measurements.

Q9: Is this laser suitable for Raman spectroscopy integration?

Yes. Its 532 nm wavelength, narrow linewidth, adjustable power, and FC output make it suitable for compatible Raman spectroscopy systems. The excitation wavelength must match the requirements of the instrument and sample.


PREVIOUS:EDGE3000 Portable Raman Spectrometer