Pt310-1 Platinum Mesh Electrode
Product Introduction
The Pt310-1 Platinum Mesh Electrode is a laboratory electrode designed for electrochemical experiments and scientific research. Manufactured from platinum mesh with a purity of 99.95%, it provides a conductive platinum working surface for applications requiring a platinum electrode.
The electrode features a PTFE stem with a diameter of 6 mm or 8 mm and a standard length of 80 mm. Available mesh configurations include square and circular shapes, with customizable dimensions to meet specific experimental requirements.
Performance Features
• High-Purity Platinum: Platinum mesh purity of 99.95%.
• Mesh Electrode Design: Provides a mesh surface for electrochemical applications.
• PTFE Electrode Stem: Available in Ø6 mm or Ø8 mm, with a standard length of 80 mm.
• Multiple Mesh Shapes: Square and circular configurations are available.
• Customizable Dimensions: Mesh shape and size can be tailored to specific experimental needs.
• Multiple Size Options: Several standard mesh dimensions are available for different laboratory setups.
Working Principle
The Pt310-1 platinum mesh electrode functions as a conductive interface between an electrochemical instrument and the electrolyte. When connected to an electrochemical measurement system, it allows electrical current to pass between the electrode surface and the solution during experiments.
Its platinum mesh structure provides an open electrode geometry, while the PTFE stem supports handling and electrical connection. The electrode can be incorporated into suitable electrochemical cells according to the experimental design.
Technical Parameters
|
Parameter |
Specification |
|
Product Model |
Pt310-1 |
|
Product Name |
Platinum Mesh Electrode |
|
Platinum Mesh Purity |
99.95% |
|
Mesh Shape |
Square or circular |
|
Electrode Stem Material |
PTFE |
|
Electrode Stem Diameter |
Ø6 mm or Ø8 mm |
|
Electrode Stem Length |
80 mm |
|
Mesh Size |
Customizable |
|
Standard Mesh Models |
Pt310, Pt315, Pt312, Pt350, Pt320, Pt330 |
Available Platinum Mesh Sizes
|
No. |
Product ID |
Mesh Specifications (mm) |
|
1 |
Pt310 |
10 × 10 |
|
2 |
Pt315 |
10 × 15 |
|
3 |
Pt312 |
10 × 20 |
|
4 |
Pt350 |
15 × 15 |
|
5 |
Pt320 |
20 × 20 |
|
6 |
Pt330 |
30 × 30 |
Note: Confirm the exact relationship between the Pt310-1 product name and the listed Pt310/Pt-series size codes when ordering.
Application Scenarios
• Electrochemical Research: Used in laboratory electrochemical experiments requiring a platinum mesh electrode.
• Electrocatalysis Studies: Suitable for experimental setups that use platinum as an electrode material.
• Electrochemical Cell Testing: Can be installed in compatible laboratory electrochemical cells.
• Materials and Chemical Research: Supports research involving electrode reactions and conductive platinum surfaces.
• Custom Laboratory Setups: Suitable for experiments requiring specific mesh shapes or dimensions.
Comparison: Platinum Mesh Electrode vs. Solid Platinum Electrode
|
Feature |
Platinum Mesh Electrode |
Solid Platinum Electrode |
|
Electrode Structure |
Open mesh structure |
Solid surface |
|
Geometry |
Square or circular mesh options |
Depends on electrode design |
|
Surface Accessibility |
Electrolyte can access the open mesh structure |
Depends on surface geometry |
|
Customization |
Mesh shape and dimensions can be customized |
Depends on product design |
|
Typical Use |
Electrochemical experiments requiring a mesh configuration |
Applications requiring a solid platinum surface |
The most suitable electrode depends on the experiment, required surface geometry, and electrochemical conditions.
Frequently Asked Questions (FAQ)
1. What is the Pt310-1 platinum mesh electrode made of?
The electrode mesh is made of platinum with a specified purity of 99.95%, and the electrode stem is made of PTFE.
2. What mesh sizes are available?
Standard options include 10 × 10 mm, 10 × 15 mm, 10 × 20 mm, 15 × 15 mm, 20 × 20 mm, and 30 × 30 mm.
3. Can I order a custom platinum mesh electrode?
Yes. The mesh shape and size can be customized to suit specific experimental requirements.
4. What shapes are available?
The platinum mesh can be supplied in square or circular shapes.
5. What are the dimensions of the PTFE stem?
The stem is available in diameters of 6 mm or 8 mm and has a standard length of 80 mm.
6. What is the benefit of a platinum mesh structure?
The open mesh geometry allows electrolyte access through the structure and can be useful in electrochemical setups where mesh electrodes are preferred.
7. What applications is this electrode suitable for?
It can be used in electrochemical research, electrocatalysis studies, laboratory cell testing, and other experiments requiring a platinum mesh electrode.
8. How should I select the right model?
Choose the mesh dimensions and shape according to the experimental setup and required electrode area. Confirm stem diameter, mounting compatibility, and other requirements with the supplier before ordering.